Search results for "Calibration protocol"
showing 4 items of 4 documents
Mathematical protocols for calibration of wastewater treatment models
2015
Activated sludge models can be very useful for designing and managing wastewater treatment plants (WWTPs). However, as with every model, they need to be calibrated for correct and reliable application. Activated sludge model calibration is still a crucial point that needs appropriate guidance. Indeed, although calibration protocols have been developed, the model calibration still represents the main bottleneck to modelling. This abstract shows a procedure for the calibration of an activated sludge model based on a comprehensive sensitivity analysis and a novel step-wise Monte Carlo-based calibration of the subset of influential parameters. The key point of the step-wise procedure is that ca…
comparing two start-up strategies for MBRs: experimental study and mathematical modelling
2012
Abstract The performance of a membrane bioreactor (MBR), and mechanisms of fouling formation, may differ due to the start-up. Therefore, the start-up can constitute an aspect that critically influences MBR performance during its lifespan. Indeed, the start-up can influence the mechanisms of membrane fouling, which is of paramount importance in an MBR. In order to gain insights on the effects of the start-up, both experimental and mathematical modelling studies were carried out on an MBR pilot plant. The MBR pilot plant constituted of a hollow fibre membrane module, in a submerged configuration, was fed by real wastewater. Two experimental periods were carried out, lasting 65 days each, char…
A practical protocol for calibration of nutrient removal wastewater treatment models
2011
Activated sludge models can be very useful for designing and managing wastewater treatment plants (WWTPs). However, as with every model, they need to be calibrated for correct and reliable application. Activated sludge model calibration is still a crucial point that needs appropriate guidance. Indeed, although calibration protocols have been developed, the model calibration still represents the main bottleneck to modelling. This paper presents a procedure for the calibration of an activated sludge model based on a comprehensive sensitivity analysis and a novel step-wise Monte Carlo-based calibration of the subset of influential parameters. In the proposed procedure the complex calibration i…
Assessing Field and Laboratory Calibration Protocols for the Diviner 2000 Probe in a Range of Soils with Different Textures
2016
Frequency domain reflectometry (FDR) downhole sensors have been increasingly used for soil moisture field monitoring because they allow measurement, even continuously, along a soil profile. Moreover, they can also be installed with minimal soil disturbance around the access tube. The objectives of the paper were to assess the field and laboratory calibration protocols for a FDR capacitance probe (Diviner 2000) for a range of soils characterized by different particle size distributions and shrink/swell potential and to propose a practical and effective protocol on the basis of undisturbed soil samples, accounting for soil shrinkage/swelling processes characterizing swelling clay soils. The e…